- FAQs » Scales & Measures
PRO 500 SCALE
Q: My scale is not zeroing. What can I be doing wrong?A: Be sure the pan is on the scale and both poises are set at zero.
Q: Can my model 500 scale be converted to a 1000 scale?
A: No, the scale has a completely different beam than the model 1000 scale has.
Q: What is this scale made of?
A: The body of the scale is made from high impact styrene.
Q: Will this affect the accuracy of the scale?
A: Not in any way.
PRO 1000 SCALE
Q: My scale is not zeroing. What can I be doing wrong?A: Be sure the pan is on the scale and both poises are set at zero. Also, do not attach the counter weight to the beam when zeroing the scale. The counter weight is only used when weighing charges or bullets over 500 grains.
Q: My counter weight does not weigh 500 grains, is this correct?
A: This is a lesser weight as it is calibrated to the end of the beam. It actually weighs approximately 260 grains, depending on the scale.
Q: My counter weight does not weigh 500 grains, is this correct?
A: This is a lesser weight as it is calibrated to the end of the beam. It actually weighs approximately 260 grains, depending on the scale.
ARCHER SCALE
Q: Can I have the scale converted to weighing powder? A. No, this scale has been calibrated to weighing arrows and shafts only, the scale would need a whole new beam and leveling assembly, it would be less expensive purchasing a different scale to weigh powder.Q: My counter weight does not weigh 500 grains, is this correct?
A: This is a lesser weight as it is calibrated to the end of the beam. It actually weighs approximately 260 grains, depending on the scale.
DPS 1200 ELECTRONIC SCALE
Below are some helpful troubleshooting hints for getting the most out of your DPS 1200 Electronic Scale:- Be sure to use the adapter supplied with the scale.
110V Adapter – Model: A21535C; AC Adapter; Class 2 Transformer
Input: 120VAC; 60Hz; 7.5W
Output: 15VAC; 350mA
220V Adapter – Model: A21531GC; AC Adapter
Input: 230V; 50Hz
Output: 15V; 310mA; 4.65VA - Verify the voltage switch on the bottom of the unit is toward the correct voltage (110V for US)
- Occasionally wipe the unit’s exterior and over the scale platform with a used non static dryer sheet such as a Bounce or ClingFree to inhibit static electricity.
- Fluorescent lights, portable and cellular phones and other electronic scales and appliances can cause erratic readings. This includes close proximity to furnaces and air conditioners.
- Scale must be placed on a stable, level surface, free of vibrations.
- Stray grains of powder under the platform will also cause the scale to “drift” and give erratic readings. Carefully lift the platform straight up and sweep away any loose powder.
- Verify the scale is in grain mode (GN in window) and that it reads 0.0 when calibrated. If any other reading is present, press the UNIT button until it reads 0.0.
- Be sure the dispensing tube is snug inside the unit.
- Keep out of drafts.
- Always allow the unit to stabilize for 24 hours if it has been in storage or out of service for a while.
- Empty immediately after using any nitro-based powders such as Tite Group and L’il Gun as this type of powder can damage the plastic parts.
- Be sure to use the restrictor plug with the DPS 3 or Upgrade Kit if the scale is overshooting.
- The Lyman DPS Electronic Scale is to be used with smokeless gun powder only. The use of any other material will void all warranties.
1000XP OR 1500XP ELECTRONIC SCALE
Below are some helpful troubleshooting hints for getting the most out of your 1000XP or 1500XP Electronic Scale:- Be sure to use the adapter supplied with the scale.
1000XP 110V Adapter; R3W012-200
1000XP 230V Adapter; R3W012-200G
1500XP 110V Adapter; A20930N or R3W009-200
1500XP 230V Adapter; A20930G - Occasionally wipe the unit’s exterior and over the scale platform with a used non static dryer sheet such as Bounce or ClingFree to inhibit static electricity.
- Fluorescent lights, portable and cellular phones and other electronic scales and appliances can cause erratic readings. This includes proximity to furnaces and air conditioners.
- Keep out of drafts.
- Always allow the unit to stabilize for 24 hours if it has been in storage or out of service for a while.
MODEL 55 POWDER MEASURE
Q: Can I use this to load black powder?A: Due to the instability of black powder particularly with static electricity, we recommend using the Model 55 Classic for this as it has an aluminum reservoir.
Q: I have an early model of the 55 Powder Measure, can I still get parts for it?
A: Some parts are still available. Any parts that are part of the metering cylinder assembly including the handle, we recommend sending the powder measure in to us for repair as over the years the parts have changed. Also we no longer have reservoirs available in the threaded style.
Q: Do the lines on the metering cylinder assembly relate to specific powder charges?
A: No, these are simply there to be used for your reference.
MODEL 55 CLASSIC POWDER MEASURE
Q: Can I really fit more powder in my cases for black powder cartridge reloading?A: Yes, the 24" drop tube used with the Classic Powder Measure allows the black powder to compress into the case. This promotes better ignition.